Superna ™ Eyeglass Service Description
Part number SEL-EyeGlass DR Design-Implement-v1 - myquotes = eyeglass-P015 Dell SKU AA977302
Revision 2 June 12, 2023
Services - Superna ™ Eyeglass PowerScale DR Design and Implementation
This service ensures the highest level of DR readiness possible for PowerScale customers with Superna Eyeglass. Recommended For: For customers that prefer to have Superna PS recommend and validate customer implementation of cluster, DNS, AD changes and validate the end to end design and implementation to achieve high level of confidence the key business data is protected for all possible DR impacts. Customers that view DR investments as a way to achieve continuous operations level of storage availability.
Description: This service is a stand alone service that provides PowerScale cluster remote implementation of cluster DR configuration required for failover using one of the supported failover modes (Access Zone dual delegation, SyncIQ or DFS mode). The configuration changes will also address SyncIQ best practices to enable a robust DR solution with PowerScale and Superna ™ Eyeglass. In addition, DR Readiness automation will be configured to ensure continuous DR testing is fully automated using the RunBook Robot feature in Superna ™ Eyeglass
Requirements to Engage Services - Mandatory to complete the service questionnaire before service team resources are assigned. The link to service questionnaire.
Access Requirements: PowerScale cluster login with admin and root access
Terms and Conditions of task covered in product maintenance agreement Support Services Agreement
Service Delivery: Remote WebEx, VPN or alternate remote access to customers PowerScale equipment. Approximately 8 days with dedicated customer technical resources.
Exclusions:
Service operates Monday to Friday 2:00 AM to 3:00 PM EDT excluding major holidays (Alternate schedules can be arranged on request)
Failover knowledge transfer cannot use customer equipment or any type of customer data.
Not a live DR service or support function for failover of production data
Not a substitute for customer developed procedural run books, (runbooks are step by step, command level documents, and include external application procedures to validate DR end to end)
Demonstration of configuration steps to be implemented will exclusively use Superna Data center resources to show procedures.
External component or software changes are excluded from all meetings including AD, DNS, PowerScale
Only PowerScale configuration will be implemented, external equipment DNS, Active Directory changes will be sent as instructions for customer to execute (with assistance via WebEx support)
customer is responsible to make all changes to all 3rd party devices or software components and have expertise in AD, DNS, Firewall, Windows, DFS, NFS sufficient to follow the directions provided by this service, 100% of all hands on changes to 3rd party product MUST be done by the customer.
Exceptions: 2 Cluster design coverage, 4 block of additional hours (part eyeglass-b4-2) added for each additional cluster requested as part of the service.
Prerequisites:
Installed Superna ™ Eyeglass appliance
Customer SME (subject Matter expert) technical contact to to make changes to PowerScale, AD, DNS, networking, host access to shares or exports
Customer IT admin knowledge of DNS or Active Directory and DFS admin teams when required for DNS, AD and DFS configuration changes are required, NFS linux environment, PowerScale hands on knowledge
Superna ™ Supplied Project Tools
Zoom or Webex account for screen sharing
Service Flow
Collection Phase - DR Design and Implementation - Interview
Review DR mode choices with customer from the Eyeglass Start Here First .
Collect cluster replication topology (Hot/Cold or Hot/Hot)
Collect SMB and NFS mounts from the cluster configuration - via Eyeglass Report
SMB mounts
current DFS usage and configuration - Get screenshot
NFS mounts
Update summary in Design document.
Collect configuration reports from Superna ™ Eyeglass for each cluster
Set Cluster RPO value in Eyeglass to customer objective for SyncIQ data loss exposure in minutes/hours per cluster)- via Eyeglass reports to validate SyncIQ schedules
Demonstrate to customer the RPO report and how to run and review the report that measures RPO compliance percentage in reports on demand.
Collect current SyncIQ configuration
SyncIQ configuration schedules (on change detection) Eyeglass report
subnet and IP used for replication, restrict at source, DNS target host using smartconnect Eyeglass report
Best practice review versus current syncIQ configuration
Collect SmartConnect Zones configuration and usage - Eyeglass report
Include in Design document summary
Collect Access zone usage - Eyeglass report
Include in Design document summary
Collect DNS resolution of Smartconnect names - nslookup
Verify nameservers returned are Subnet service ip from each cluster.
Include in Design document summary
Design SmartConnect failover mappings for Pool to Pool mappings between sites - Eyeglass report
Requires IP pool to IP pool mapping between cluster sites
Update design document mapping table aliases for each pool that is recommended. Customer to make these changes to the environment.
Collect Active Directory information (domain name, machine account names) - Eyeglass report
Demonstrate AD delegation using documentation link How to Configure Delegation of Cluster Machine Accounts with Active Directory Users and Computers Snapin
Customer to complete delegation steps with AD administrator
Test AD delegation is completed correctly using document How to Validate AD Cluster Delegation is Ready for Failover and failback of SPNs published.
Customer sign off on phase completed - Email to acknowledge
Design Phase - DR configuration
Recommend failover solution presented to customer based on Collection Phase
All Access Zone changes on the cluster are covered in this section and documented in the design document.
Includes AD delegation SPN failover
Smartconnect name changes and DNS delegation changes
configuration sync issue resolution
syncIQ policy configuration changes
Eyeglass configuration changes
DFS (if used) changes
pool mapping aliases for failover (access zone or pool failover)
Build Cluster Change Management plan including order and CLI commands needed to be executed by customer and validated by Superna - Customer Deliverable document
Build the plan in two phases online changes and maintenance window changes - Customer Deliverable document
Review design document with customer (webex) sign off on design and configuration change plan before proceeding to next phase
Customer sign off on phase completed - Email to acknowledge
Continuous DR Automation Design and Configure Phase - RunBook Robot Access Zone Failover Automation
Design an Access Zone for Run Book Robot feature to implement daily failover and failover for DR Readiness
Review Runbook robot configuration requirements (guide Eyeglass Runbook Robot Guide)
Configure Robot access zone, ip pools, DNS delegation - Requires customer administrators.
Execute Robot Access Zone failover - Via Webex
Verify successful failover and failback
Review success and failover of robot policies and how to check completion
Review how to change schedule
Review how to run manually for DR testing
Review how to customize with test data and additional shares, exports and quotas
Customer sign off on phase completed - Email to acknowledge
Knowledge Transfer phase: - Via Webex 1-2 hours
Review failover planning guide on how to plan a failover
Review best practices guide on how to execute steps pre-failover and verify the cluster environment before any failover
Review failover release notes document on last minute release specific steps or instructions
Review DR assistant validation screen warnings and process for open files
Review failover logs in detail to explain how to read them and diagnose successful vs unsuccessful steps
Review failover recovery guide and how to use this to recovery from failed steps
Review process to raise support request correctly to get failover log analysis completed.
Customer sign off on phase completed - Email or basecamp post to acknowledge
Implementation phase:
In collaboration with customer apply configuration changes defined in the build design document following execution plan.
Customer applies changes coordinating with SME within customer organization to apply changes from the design guide document.
Superna validates DNS and SmartConnect dual delegation (if implemented), DFS configuration, Active Directory SPN configuration, SyncIQ policy updates, IP pools mapping (if implemented), Eyeglass configuration and job definitions and DR dashboard.
Submit support logs for validation of correct configuration.
Scheduled via multiple webex sessions with customer technical resources based on change management requirements
Customer sign off on phase completed - Email to acknowledge
Validation phase: via Webex
Checklist validation on design with Eyeglass UI and support log analysis
Customer sign off on phase completed - Email to acknowledge