Software Releases
Release 2.5.5 - Release Notes ECA
Home


These Release Notes cover the Superna Eyeglass ECA deployed with Superna Eyeglass Ransomware Defender and Superna Eyeglass Easy Auditor

What’s New in Superna Eyeglass Easy Auditor Edition and Ransomware Defender Edition

Release 2.5.5

What’s New! In Superna Eyeglass Easy Auditor Edition and Ransomware Defender Edition Release 2.5.5 can be found here.




Supported OneFS releases

8.0.0.x

8.0.1.x

8.1.x.x

8.2.x.x


Supported Eyeglass releases

Superna Eyeglass ECA Version


Superna Eyeglass Version


2.5.5-192342.5.5-19234
2.5.5-192262.5.5-19226
2.5.5-19219
2.5.5-19219
2.5.5-191882.5.5-19188

2.5.5-19184

2.5.5-19184



End of Life Notifications


Description

End of Life Date

1.9.x


All customers running the above releases should upgrade to the latest  release using upgrade guide located here.  Numerous functional and performance improvements exist in later releases so earlier releases are end of support with all new cases requiring an upgrade.


March 20, 2018

2.5.0, 2.5.1, 2.5.2

All customers running the above releases should upgrade to the latest  release using upgrade guide located here.  Numerous functional and performance improvements exist in later releases so earlier releases are end of support with all new cases requiring an upgrade.

July 31, 2019

2.5.3

All customers running the above releases should upgrade to the latest  release using upgrade guide located here.  Numerous functional and performance improvements exist in later releases so earlier releases are end of support with all new cases requiring an upgrade

December 31, 2019

2.5.4

All customers running the above releases should upgrade to the latest  release using upgrade guide located here.  Numerous functional and performance improvements exist in later releases so earlier releases are end of support with all new cases requiring an upgrade


March 31, 2020


Issues Fixed in this Release

Fixed in 2.5.5-19234

T13000 kafka manager consumes disk space

kafka manager component used for troubleshooting and diagnostics can consume too much disk space in some environments.

Resolution: kafka manager component no longer runs by default. It will be started and stopped manually as required for troubleshooting and diagnostics.


Known Issues

General


T8309 ecactl cluster up may continue despite hbase errors

In some cases the "ecactl cluster up" command may continue when it encounters hbase errors. 

Workaround: Please open a support case support.superna.net for assistance with hbase errors.

—————————————————–

T7867  Issues when ecactl cluster up interrupted

Interrupting "ecactl cluster up" before it has completed may result in misconfigured references for ECA nodes. This can result in ECA components starting on incorrect ECA node or may prevent ECA components from coming up at all.

Resolution: Please open a support case support.superna.net for assistance. 

—————————————————–


Known Limitations

General


T8228 ECA Alarms not cleared automatically

ECA related alarms that appear in the Eyeglass Alarms window will not be cleared automatically. 

Workaround: Alarms must be manually cleared. Open the Alarms window on the Eyeglass web interface and select the Clear link for the alarm that you would like to clear.

—————————————————–

© Superna LLC